Grant Aerona 290
Grant’s inverter-driven air-to-water heat-pump range combines natural R290 refrigerant, high seasonal efficiency, multiple outputs and Quiet Mark accredited acoustic design.
Final model, capacity, cylinder and system design are subject to a property survey and room-by-room heat-loss calculation.
Why consider the Grant Aerona 290?
4 to 15.5kW range
Single-phase outputs include 4, 6.5, 9, 12 and 15.5kW, with the final model selected from the property heat-loss design.
A+++ at 35°C
Every Aerona 290 model is rated A+++ at 35°C water flow and A++ at 55°C.
Natural R290 refrigerant
The range uses natural R290 refrigerant with dedicated safety features and installer protection-zone requirements.
High seasonal performance
Grant publishes SCOP figures up to 5.08 at 35°C water flow, depending on model.
Quiet Mark accredited
Sound-reducing casing and compressor features help the range achieve Quiet Mark accreditation.
Aerona Smart Controller
Compatible smart controls support weather and load compensation, remote management and installer diagnostics.
Specifications vary by model, output and system configuration. JMG Renewables will identify the exact model in your written quotation. View manufacturer information.
Is this system suitable for your home?
Homes requiring a modern monobloc heat pump across a broad output range, subject to heat-loss design and R290 installation requirements.
Suitability depends on calculated heat loss, required flow temperature, radiator or underfloor-heating performance, electrical supply, hot-water demand, pipe routes and outdoor-unit positioning.
Your survey should confirm
- Required heating output
- Design flow temperature
- Radiator or emitter upgrades
- Hot-water cylinder capacity
- Outdoor-unit location and acoustics
- Electrical and pipework requirements
Grant Aerona 290 gallery






Official Grant Aerona 290 information
Review Grant UK’s full technical specifications, downloads and product information for the Aerona 290 range.
Guarantee wording
Grant states that eligible G1 installers who have completed the required Grant heat-pump training may offer a seven-year guarantee, subject to Grant’s terms. JMG will confirm the applicable guarantee in your written quotation.
What your quotation can include
- Correctly sized heat pump
- Suitable hot-water cylinder
- Room-by-room heat-loss calculation
- System design and controls
- Outdoor-unit mounting arrangement
- Required plumbing and electrical work
- Emitter upgrades where needed
- Installation and commissioning
- MCS documentation and grant application
- Handover, warranty registration and aftercare
Equipment is selected for the property rather than promised as a fixed standard package.
Boiler Upgrade Scheme support
Standard heat-pump grant
Eligible homeowners may receive £7,500 towards an eligible air-to-water heat-pump installation.
Eligible off-grid oil or LPG homes
A higher grant may be available for qualifying off-gas-grid properties currently heated by oil or LPG.
Eligibility and voucher approval are subject to the current scheme rules. JMG applies for the voucher on the customer’s behalf as the installer.
Compare other heat-pump systems
| System | Type | May suit |
|---|---|---|
| Grant Aerona 290 | Split air-to-water | Homes requiring a modern monobloc heat pump across a broad output range, subject to heat-loss design and R290 installation requirements. |
| Daikin Altherma 3 small monobloc | Compact monobloc | Suitable smaller homes where the calculated heat load matches the available low-capacity range. |
| Daikin Altherma 3 large monobloc | Higher-output monobloc | Larger or higher-loss properties requiring more output after a full heat-loss calculation. |
| Vaillant aroTHERM plus | Premium monobloc | Retrofit and new-build projects needing a premium system with a wide capacity range. |
| Panasonic Aquarea | Model-dependent range | A wide variety of new-build, retrofit and colder-climate requirements. |
| Grant Aerona 290 | R290 monobloc | Homes requiring a broad output range, high seasonal efficiency and Quiet Mark accredited design |
From survey to aftercare
Survey
Property, heating system, hot water and equipment locations assessed.
Design
Heat loss, capacity, cylinder and emitter requirements calculated.
Quote and grant
Written specification prepared and eligible grant process supported.
Installation
System installed, commissioned, handed over and supported.
Grant Aerona 290 FAQs
What capacity do I need?
The correct capacity must be calculated from a room-by-room heat-loss assessment. Floor area alone is not enough.
What cylinder size will be included?
The cylinder is selected for household hot-water demand, available space and the system design rather than supplied as one fixed size.
Will my radiators need replacing?
Existing emitters are checked against the required system temperatures. Only the upgrades required by the design should be included.
Is the installation free with the grant?
No. The grant contributes towards an eligible installation; the remaining cost depends on the property-specific quotation.
Can JMG service the system?
Request a Grant Aerona 290 survey
Tell us about your property and current heating system. JMG Renewables will contact you to discuss the next step.
Stripe and Klarna available at checkout. Where offered, choose Klarna securely through our Stripe payment page. Availability is subject to Klarna’s approval and terms.